Eaton electrical component starter profiles
Browse 27 editable entries covering industrial control, protection, power distribution, drives, and panel devices for machine panels and low-voltage distribution. These independent profiles connect schematic intent to terminal semantics and dimensioned panel geometry.
Eaton Protection components
- Eaton FAZ-B6/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-B10/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-B16/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-B20/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-B25/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-B32/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-C6/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-C10/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-C16/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton FAZ-C20/1 — FAZ miniature circuit breaker starter profile with editable geometry and a typed terminal recipe.; 18 × 83 × 75 mm panel envelope.
- Eaton ZB12-4 — ZB12 thermal overload relay starter profile, current setting range 2.4–4 A, for direct mounting under DILM7–DILM15 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 68 × 70 mm panel envelope.
- Eaton ZB12-6 — ZB12 thermal overload relay starter profile, current setting range 4–6 A, for direct mounting under DILM7–DILM15 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 68 × 70 mm panel envelope.
- Eaton ZB12-10 — ZB12 thermal overload relay starter profile, current setting range 6–10 A, for direct mounting under DILM7–DILM15 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 68 × 70 mm panel envelope.
- Eaton ZB12-12 — ZB12 thermal overload relay starter profile, current setting range 9–12 A, for direct mounting under DILM7–DILM15 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 68 × 70 mm panel envelope.
- Eaton ZB12-16 — ZB12 thermal overload relay starter profile, current setting range 10–16 A, for direct mounting under DILM7–DILM15 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 68 × 70 mm panel envelope.
- Eaton ZB32-24 — ZB32 thermal overload relay starter profile, current setting range 16–24 A, for direct mounting under DILM17–DILM38 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 75 × 85 mm panel envelope.
- Eaton ZB32-32 — ZB32 thermal overload relay starter profile, current setting range 24–32 A, for direct mounting under DILM17–DILM38 contactors. Main poles 1/L1-3/L2-5/L3 to 2/T1-4/T2-6/T3; auxiliary 95-96 NC trip contact and 97-98 NO alarm contact. Starter profile — verify setting range, trip class and dimensions against the current datasheet.; 45 × 75 × 85 mm panel envelope.
Eaton Control components
- Eaton DILM7-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM9-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM12-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM17-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM25-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM32-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM40-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM50-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM65-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
- Eaton DILM80-10(24VDC) — DILM three-pole contactor starter profile with editable geometry and a typed terminal recipe.; 45 × 85 × 92 mm panel envelope.
Official manufacturer sources
- Eaton official product catalogue (source checked 2026-07-13).
Verification boundary
CircuitDiagramMaker is independent from Eaton. These are editable starter profiles, not certified CAD data, an endorsement, or a substitute for the exact current datasheet. Verify catalog number, revision, terminals, dimensions, ratings, tolerances, cutouts, clearances, accessories, and installation instructions before construction.
Open the component library or browse all control-panel components.