MEAN WELL MDR-40-24 Dimensions & Terminal Map
MEAN WELL MDR-40-24 is available as an editable manufacturer starter profile for 2D panel and 3D panel. It links a 40 × 90 × 100 mm panel envelope reference envelope to 5 typed terminals and 2 schematic units; verify every value against the current official product documentation.
- Library ID
- mean-well-mdr-40-24
- Manufacturer
- MEAN WELL
- Catalog number
- MDR-40-24
- Product family
- MDR series
- Profile status
- Editable starter profile; verify official data
- Typed terminals
- 5
- Automation readiness
- auto wire ready
- Category
- Power
- Editor symbol
- power-supply-24v
- Available in
- 2D panel, 3D panel
- Panel envelope
- 40 × 90 × 100 mm
- Mounting
- Din rail
- 3D asset family
- Box
Official manufacturer source
Check the current manufacturer documentation. Source link checked 2026-07-13.
Physical terminals mapped to design intent
This auto wire ready profile describes typed terminal roles and symbol-pin mappings. It still requires an explicit user-selected wiring recipe.
| Terminal | Label | Role | Domain | Direction |
|---|---|---|---|---|
| L | AC line | line | power | input |
| N | AC neutral | neutral | power | input |
| PE | Protective earth | protective earth | earth | input |
| + | DC positive | dc positive | power | output |
| - | DC return | dc return | power | output |
What this component entry includes
The MEAN WELL MDR-40-24 starter profile combines the “power-supply-24v” symbol family with editable panel geometry, typed terminal semantics, and 2 schematic-unit mappings. It is designed to accelerate part selection and validation without presenting community-maintained data as manufacturer-certified.
- Library ID: mean-well-mdr-40-24
- Manufacturer: MEAN WELL
- Catalog number: MDR-40-24
- Product family: MDR series
- Profile status: Editable starter profile; verify official data
- Typed terminals: 5
How it behaves in the editor
Add the part from the physical component library, then position it in 2D panel. The editor stores the physical part ID with the placed device so the schematic record, selected footprint, panel position, and reports remain connected instead of becoming unrelated drawings.
- Dimensioned footprint in the 2D enclosure view
- Shape-specific 3D geometry instead of an anonymous box
- Mounting classification: din rail
- Collision and enclosure-boundary checks
- GLB visualization export in metre units
Verify and version this manufacturer profile
Open the official source below, compare the exact suffix and current revision, then correct the envelope, ratings, terminal map, and mounting details where required. When placed, the editor stores a versioned snapshot so future library changes cannot silently alter an issued project.
- Check the latest manufacturer dimensional drawing
- Verify terminal or pad numbering against the schematic
- Confirm installation clearance and heat-dissipation requirements
- Record the exact catalog number and datasheet URL in the project
Use this component in five steps
- Open 2D panel and search for “MEAN WELL MDR-40-24” in the Components panel.
- Place the part, then select it to review its engineering and physical properties.
- Open the official manufacturer source and verify the full catalog suffix, current status, dimensions, ratings, and terminal designations.
- Position it on the backplate, DIN rail, or door; then check overlap and enclosure boundaries in 2D and 3D.
- Save or release the project so the selected physical data stays with the issued design.
Engineering boundaries
- This is an independent, editable starter profile—not a manufacturer-certified CAD model and not an affiliation or endorsement. Check the linked official source and confirm the exact ordered product, revision, terminal numbering, ratings, dimensions, tolerances, clearances, and cutout before fabrication.
- The 3D asset is parametric visualization geometry and GLB handoff, not an imported STEP/Parasolid manufacturer model.
- Electrical ratings shown in project fields are documentation inputs; they are not automatically certified against regional codes or the component datasheet.
Frequently asked questions
Is the MEAN WELL MDR-40-24 available in the online editor?
Yes. Search for it in the Components panel while using 2D panel and 3D panel. The placed component keeps the library ID with its engineering record.
What dimensions does this MEAN WELL MDR-40-24 entry use?
The editable catalog profile uses 40 × 90 × 100 mm panel envelope. These are starting dimensions and should be checked against the exact ordered part and its current manufacturer drawing.
Can I change the dimensions or terminal map?
Yes. Use the custom part builder to copy a compatible archetype, then define manufacturer, catalog number, width, height, depth, mounting, physical terminals, semantic roles, and symbol-pin mappings. Placed devices retain an immutable revision snapshot.
Is this a manufacturer-certified model?
This is an independent, editable starter profile—not a manufacturer-certified CAD model and not an affiliation or endorsement. Check the linked official source and confirm the exact ordered product, revision, terminal numbering, ratings, dimensions, tolerances, clearances, and cutout before fabrication.