Data Link Connector Wiring Diagram — Free & Editable

Data link connector wiring diagram showing 16-pin OBD-ii connector, fuse and battery with 9 wired connections
Data Link Connector Wiring Diagram — Free & Editable — interactive diagram. Open it in the editor to customise components and wiring.

This is a free printable data link connector wiring diagram: download the diagram as SVG or open it and print to paper or PDF.

This Data link connector wiring diagram shows 10 components and 9 routed connections, including 1 × X1 (Obd Connector), 2 × GND (chassis ground), 1 × Pin 5 · Signal ground (Terminal Block), 1 × Pin 6 · CAN High (Terminal Block) and 1 × Pin 7 · K-line (Terminal Block). Use it to inspect the shown topology, then confirm ratings and terminal assignments against the equipment documentation for your installation.

Diagram checks and scope

Components
10
Wired connections
9
Automated check
Automated pin, route, source, and topology checks passed; this is not a safety certification.

What this Data Link Connector Wiring Diagram drawing contains. The rendered example uses 1 × X1 (Obd Connector), 2 × GND (chassis ground), 1 × Pin 5 · Signal ground (Terminal Block), 1 × Pin 6 · CAN High (Terminal Block), 1 × Pin 7 · K-line (Terminal Block), 1 × Pin 14 · CAN Low (Terminal Block), 1 × F1 (Ind Fuse), 1 × B1 (Battery) and 1 × Pin 15 · L-line (Terminal Block). Connector diagrams are orientation-sensitive: a mating-face view, wire-entry view and mirrored receptacle view can assign the same position differently. The component names in the list below come from the editable canvas, while the wire summary comes from the saved start and end terminals. This makes the written explanation auditable against the image instead of presenting an unrelated stock circuit.

Reading the stored graph from terminal to terminal gives this sequence: 1. X1 gnd terminal connects to GND gnd terminal. 2. X1 sgnd terminal connects to Pin 5 · Signal ground right terminal. 3. X1 can h terminal connects to Pin 6 · CAN High left terminal. 4. X1 k line terminal connects to Pin 7 · K-line left terminal. 5. X1 can l terminal connects to Pin 14 · CAN Low right terminal. 6. X1 batt terminal connects to F1 out terminal. 7. F1 in terminal connects to B1 pos terminal. 8. B1 neg terminal connects to GND gnd terminal. 9. X1 l line terminal connects to Pin 15 · L-line left terminal. The drawing uses terminal endpoints rather than relying on unverified colour conventions. A line joining two terminals records electrical continuity in this reference; visual proximity alone does not create a connection. Junctions, bridges and terminal labels therefore matter when the drawing is edited or exported.

Trace by terminal identifier and function, not by apparent left-to-right position. Shield, chassis and signal returns are separate concepts unless the governing connector documentation explicitly bonds them. In this particular graph, the first visible path is X1 gnd terminal connects to GND gnd terminal., X1 sgnd terminal connects to Pin 5 · Signal ground right terminal., X1 can h terminal connects to Pin 6 · CAN High left terminal. and X1 k line terminal connects to Pin 7 · K-line left terminal.. Follow the remaining rows in the connection table before changing a symbol or moving a conductor, because a neat layout is not evidence that a terminal function is correct.

Confirm connector gender, viewing side, keying, revision and every signal assignment against the applicable standard or manufacturer drawing. Perform continuity and short checks on an unpowered cable before connection. Automated validation checks that component IDs and terminal IDs exist, routes terminate on pins, the graph has a recognized source, and the saved topology has no blocking structural fault. It does not determine conductor size, protective-device rating, fault current, insulation class, environmental suitability or compliance with local rules. Those decisions require project values and the current primary documentation.

How to wire data link connector wiring diagram

  1. Read the Data Link Connector Wiring Diagram source path For this data link connector wiring diagram, begin at X1 (Obd Connector) and trace every stored terminal pair toward the load or output; do not infer continuity from lines that merely cross.
  2. Match every terminal name Compare the Data Link Connector Wiring Diagram terminal labels shown in the connection table with the current device or standard documentation before assigning real conductors.
  3. Set project-specific ratings Replace placeholder values in the data link connector wiring diagram with verified voltage, current, protection, conductor and environmental data for the actual installation.
  4. Run the electrical checks again After editing GND (chassis ground) or any route, validate the graph and inspect every reported open terminal, source fault, collision and disconnected island.
  5. Release a controlled copy Export the revised Data Link Connector Wiring Diagram drawing only after a competent reviewer has compared it with the bill of materials, manufacturer documents and applicable rules.

Specifications

TopicData Link Connector Wiring Diagram
Components shown10
Routed connections9
Named netsNone stored
Verification scopeStored pins, routes, source path and graph topology

Safety warnings

Tools needed

Common mistakes

Troubleshooting

The Data Link Connector Wiring Diagram path appears open
Cause: A route ends on the wrong pin, a terminal was renamed, or a required return path is absent. Fix: Trace the connection rows in order, restore the documented terminal mapping, and run validation again.
The edited drawing passes visually but validation fails
Cause: A conductor may stop off-pin, cross a component body, create a source short or leave a disconnected island. Fix: Open each blocking finding, correct the referenced component or route, then re-run the topology check before export.
The real equipment behaves differently
Cause: The stored reference does not match the exact model, revision, supply or contact state. Fix: De-energize safely, return to the current primary documentation, and revise the symbol terminals and values before further testing.

Frequently asked questions

What exactly is verified on this data link connector wiring diagram?

The saved Data Link Connector Wiring Diagram graph is checked for known components and terminals, pin-snapped routes, a recognizable source path and blocking topology defects. Exact equipment ratings and manufacturer assignments are outside that automated scope.

Which components are actually shown in this Data Link Connector Wiring Diagram diagram?

The current editable graph contains 1 × X1 (Obd Connector), 2 × GND (chassis ground), 1 × Pin 5 · Signal ground (Terminal Block), 1 × Pin 6 · CAN High (Terminal Block), 1 × Pin 7 · K-line (Terminal Block), 1 × Pin 14 · CAN Low (Terminal Block), 1 × F1 (Ind Fuse), 1 × B1 (Battery) and 1 × Pin 15 · L-line (Terminal Block). The bill of materials on this page is derived from those saved symbols rather than a generic shopping list.

How are the data link connector wiring diagram connections documented?

The graph contains 9 terminal-to-terminal links. The first path shown is X1 gnd terminal connects to GND gnd terminal.

Can I use the drawing as an installation instruction?

Use it as an editable reference and review aid. Verify the exact equipment documentation, ratings, protection, conductor selection and local requirements before construction or release.

Sources and verification

Review status: Not independently reviewed. Automated topology checks confirm stored terminals and routes, not the correctness of manufacturer pin assignments, ratings, regional codes, or installation decisions. Verify those claims against the current primary documentation before use.

Related diagrams

Free electrical calculators

Edit this diagram free in the online editor