Timed Contact NC, Off-Delay (55-56) Symbol

Timed Contact NC, Off-Delay (55-56) schematic symbol
The Timed Contact NC, Off-Delay (55-56) schematic symbol. Standard-specific details are listed below where available.

Definition: The off-delay NC timed contact is a normally closed contact operated by an off-delay timer: it opens immediately when the timer coil is energised and recloses only after the set time has elapsed from the moment the coil is de-energised.

Also known as: off-delay NC contact, TOF NC contact, time-delayed closing break contact, NCTC contact, timer NC contact 55-56 off-delay.

What the Timed Contact NC, Off-Delay (55-56) symbol means

This symbol marks a circuit that is broken while the control signal is present and stays broken for a fixed time after the signal goes away, for example a restart lock-out. It is drawn closed, with the delay arc showing that the reclosing movement is the slow one.

How to identify the Timed Contact NC, Off-Delay (55-56) symbol

Look for a normally closed (break) contact with the semicircular delay arc linked to the blade, oriented so that the reclosing movement runs towards the centre of the arc. It carries the timer's tag and terminals such as 55-56.

Live editor identity: Live-library identity: `off-delay-contact-nc`, 40 × 60 canvas units, 2 logical terminals. Match this exact SVG and terminal list when identifying the placeable editor symbol; do not identify a physical package from the schematic outline alone.

Function and usage boundary

Energising the timer coil opens the contact at once. De-energising the coil starts the delay and the contact stays open until the delay ends, then recloses.

Usage boundary: Use the Timed Contact NC, Off-Delay (55-56) abstraction only when the intended circuit can be expressed through these logical ports: `in` (55), `out` (56). Select a versioned physical profile and exact manufacturer datasheet before assigning package pins, ratings, or fabrication dimensions.

Standards: IEC vs ANSI

IEC 60617IEC 60617 draws a timed contact as an ordinary make or break contact with the delayed-action mark (a small arc, the 'parachute') linked to the moving blade. Movement towards the centre of the arc is the delayed one, so the arc's orientation tells you whether the delay applies on operation (on-delay) or on release (off-delay). Terminal numbers follow EN 50005 practice: the function digit 5-6 marks a time-delayed break (NC) contact and 7-8 a time-delayed make (NO) contact, e.g. 55-56 and 67-68 on add-on timer blocks; single-function timer relays often use 15-16 (NC) and 15-18 (NO) for a timed changeover.
ANSI/IEEE 315ANSI/IEEE 315 and NEMA ICS practice draw the same function as a contact with an arrowed arc and the abbreviations TDC/TC (time delay closing) or TDO/TO (time delay opening), and label the contact with the timer's device tag (TR1, 2TR) rather than IEC function digits.
Key differenceBoth systems mark the delayed direction on the contact itself. IEC uses the parachute arc plus EN 50005 terminal digits (55-56, 67-68); North American drawings use NOTC/NCTO-style abbreviations and the TR device tag.

The displayed SVG is the live editor implementation, not a licensed reproduction or certification of an IEC or IEEE database glyph. Verify the exact official entry and project edition before issuing work.

Variant availability

Logical terminals

The live editor exposes `in` (55), `out` (56). These are stable logical terminal IDs for diagram connectivity, not a promise that they equal physical package pin numbers.

Logical IDEditor terminal name
in55
out56

Polarity and direction

This editor symbol does not encode a universal positive/negative orientation. Do not infer physical polarity or package pin numbering from left/right placement alone.

Reference designator

Project-defined: No single reference letter is asserted for this broad symbol. Apply the project standard and equipment-classification rules consistently.

Where the Timed Contact NC, Off-Delay (55-56) symbol is used

Key facts

Common interpretation mistakes

Frequently asked questions

How is an off-delay NC different from an on-delay NC?

Both are closed at rest. The on-delay NC opens after the delay once the coil is energised and recloses immediately; the off-delay NC opens immediately and recloses after the delay once the coil is de-energised.

How is a timed contact linked to its timer?

By its device tag. The contact carries the same tag as the timer coil (for example KT1), and the cross-reference under the coil lists every contact it operates. In this editor the simulator links them the same way, so give the contact the timer's label.

What do 55-56 and 67-68 mean?

They are EN 50005 terminal numbers. The first digit is the contact's sequence number on the device; the second is the function digit, where 5-6 means a time-delayed break (NC) contact and 7-8 a time-delayed make (NO) contact. Ordinary instantaneous contacts use 1-2 (NC) and 3-4 (NO).

Sources and verification

Geometry fingerprint: 2e53cf83a1f2413e. A changed SVG, canvas size, or terminal definition invalidates the recorded review.

Related symbols

Physical breadboard, PCB, and panel mapping

No universal physical profile is published for this symbol yet. Create a versioned custom part from the exact manufacturer dimensions and terminal map before fabrication.

Place the Timed Contact NC, Off-Delay (55-56) symbol directly on a wiring diagram or schematic in the free online editor — no download required.