Timed Contact NO, On-Delay (67-68) Symbol

Timed Contact NO, On-Delay (67-68) schematic symbol
The Timed Contact NO, On-Delay (67-68) schematic symbol. Standard-specific details are listed below where available.

Definition: The on-delay NO timed contact is a normally open contact operated by an on-delay timer: it closes only after the set time has elapsed from the moment the timer coil is energised, and it opens immediately when the coil is de-energised.

Also known as: on-delay NO contact, TON contact, time-delayed make contact, delayed closing contact, NOTC contact, timer NO contact 67-68.

What the Timed Contact NO, On-Delay (67-68) symbol means

On a schematic this symbol says 'this circuit is made a fixed time after the timer starts'. It is drawn in the de-energised state (open), with the delay arc showing that the closing movement is the slow one. If the timer coil drops out before the delay runs out, the contact never closes and the timing restarts from zero next time.

How to identify the Timed Contact NO, On-Delay (67-68) symbol

Look for a normally open contact with a small semicircular arc joined to the blade by a double line. On an on-delay NO contact the closing movement runs towards the centre of the arc. It carries the timer's tag (KT1, KF2) and terminals such as 67-68, or 15-18 on a single-function timer relay.

Live editor identity: Live-library identity: `on-delay-contact-no`, 40 × 60 canvas units, 2 logical terminals. Match this exact SVG and terminal list when identifying the placeable editor symbol; do not identify a physical package from the schematic outline alone.

Function and usage boundary

When the timer coil is energised the timing period starts; the contact stays open until the delay ends, then closes and stays closed for as long as the coil remains energised. Removing coil power opens it at once and resets the timer.

Usage boundary: Use the Timed Contact NO, On-Delay (67-68) abstraction only when the intended circuit can be expressed through these logical ports: `in` (67), `out` (68). Select a versioned physical profile and exact manufacturer datasheet before assigning package pins, ratings, or fabrication dimensions.

Standards: IEC vs ANSI

IEC 60617IEC 60617 draws a timed contact as an ordinary make or break contact with the delayed-action mark (a small arc, the 'parachute') linked to the moving blade. Movement towards the centre of the arc is the delayed one, so the arc's orientation tells you whether the delay applies on operation (on-delay) or on release (off-delay). Terminal numbers follow EN 50005 practice: the function digit 5-6 marks a time-delayed break (NC) contact and 7-8 a time-delayed make (NO) contact, e.g. 55-56 and 67-68 on add-on timer blocks; single-function timer relays often use 15-16 (NC) and 15-18 (NO) for a timed changeover.
ANSI/IEEE 315ANSI/IEEE 315 and NEMA ICS practice draw the same function as a contact with an arrowed arc and the abbreviations TDC/TC (time delay closing) or TDO/TO (time delay opening), and label the contact with the timer's device tag (TR1, 2TR) rather than IEC function digits.
Key differenceBoth systems mark the delayed direction on the contact itself. IEC uses the parachute arc plus EN 50005 terminal digits (55-56, 67-68); North American drawings use NOTC/NCTO-style abbreviations and the TR device tag.

The displayed SVG is the live editor implementation, not a licensed reproduction or certification of an IEC or IEEE database glyph. Verify the exact official entry and project edition before issuing work.

Variant availability

Logical terminals

The live editor exposes `in` (67), `out` (68). These are stable logical terminal IDs for diagram connectivity, not a promise that they equal physical package pin numbers.

Logical IDEditor terminal name
in67
out68

Polarity and direction

This editor symbol does not encode a universal positive/negative orientation. Do not infer physical polarity or package pin numbering from left/right placement alone.

Reference designator

Project-defined: No single reference letter is asserted for this broad symbol. Apply the project standard and equipment-classification rules consistently.

Where the Timed Contact NO, On-Delay (67-68) symbol is used

Key facts

Common interpretation mistakes

Frequently asked questions

What is the difference between an on-delay NO and an off-delay NO contact?

Both are open at rest. The on-delay NO waits for the set time before closing after the coil is energised, then opens immediately. The off-delay NO closes immediately and waits for the set time before opening after the coil is de-energised.

How is a timed contact linked to its timer?

By its device tag. The contact carries the same tag as the timer coil (for example KT1), and the cross-reference under the coil lists every contact it operates. In this editor the simulator links them the same way, so give the contact the timer's label.

What do 55-56 and 67-68 mean?

They are EN 50005 terminal numbers. The first digit is the contact's sequence number on the device; the second is the function digit, where 5-6 means a time-delayed break (NC) contact and 7-8 a time-delayed make (NO) contact. Ordinary instantaneous contacts use 1-2 (NC) and 3-4 (NO).

Sources and verification

Geometry fingerprint: 0b3dd1caa7cdb9ea. A changed SVG, canvas size, or terminal definition invalidates the recorded review.

Related symbols

Physical breadboard, PCB, and panel mapping

No universal physical profile is published for this symbol yet. Create a versioned custom part from the exact manufacturer dimensions and terminal map before fabrication.

Place the Timed Contact NO, On-Delay (67-68) symbol directly on a wiring diagram or schematic in the free online editor — no download required.